Quick Answer
Calculate AISC LRFD Bolt Shear Capacity per Fastener (Single Shear)
Calculator
Need Equipment or a Supplier for This Project?
Use your calculation result to continue with equipment selection, supplier discovery, engineering support, or project evaluation.
Find Engineering Solutions →Result Interpretation
AISC LRFD Bolt Shear Capacity per Fastener (Single Shear) calculator computes Design Shear Strength per Bolt in N using the defined engineering formula and the input values provided. Design Shear Strength per Bolt is expressed in N. No universal acceptance threshold is defined by this calculator.
Worked Example
Verified calculation
Given:
- LRFD Shear Resistance Factor = 0.75
- Nominal Shear Strength of Bolt = 482634000
- Bolt Nominal Area = 0.000113411
Expected Result:
- Design Shear Strength per Bolt = 41052.0034305
Engineering Interpretation:
Under the given input conditions, the calculated result is: Design Shear Strength per Bolt = 41052.0034305 N.
The actual numerical result is computed by the Runtime engine using the persisted tool definition. The values shown here come from deterministically validated test cases.
Formula / Method
design shear strength per bolt = lrfd shear resistance factor * nominal shear strength of bolt * bolt nominal areaFormula family: formula_bim_bim_structural_connection_bolt_shear_capacity_checker_aisc_lrfd
Variables
| Symbol | Label | Role | Description |
|---|---|---|---|
| phi_v | LRFD Shear Resistance Factor | INPUT | LRFD Shear Resistance Factor |
| Fnv | Nominal Shear Strength of Bolt | INPUT | Nominal Shear Strength of Bolt |
| Ab | Bolt Nominal Area | INPUT | Bolt Nominal Area |
| result | Design Shear Strength per Bolt | OUTPUT | Design Shear Strength per Bolt |
Calculation Steps
- Enter the lrfd shear resistance factor in dimensionless.
- Enter the nominal shear strength of bolt in Pa.
- Enter the bolt nominal area in m^2.
- Step 1: Compute design shear strength per bolt.
- Read the design shear strength per bolt (N) from the results.
Engineering Summary
Calculate AISC LRFD Bolt Shear Capacity per Fastener (Single Shear)
Frequently Asked Questions
What does this calculator calculate?
The AISC LRFD Bolt Shear Capacity per Fastener (Single Shear) calculator estimates Design Shear Strength per Bolt based on the input parameters you provide
Why is lrfd shear resistance factor important in this calculation?
lrfd shear resistance factor is directly proportional to design shear strength per bolt. When you enter lrfd shear resistance factor in dimensionless, the calculator uses it in the engineering formula to compute the output
How should I interpret the result design shear strength per bolt?
The calculator outputs design shear strength per bolt in N. For larger forces, you can divide by 1000 to express the result in kN. The result is computed directly from the input values using the defined engineering formula
What units should I use for the inputs?
Enter each value in the units shown next to the input field: LRFD Shear Resistance Factor (dimensionless), Nominal Shear Strength of Bolt (Pa), Bolt Nominal Area (m^2). Make sure all inputs use the specified units for consistent results
What assumptions does this calculator use?
This calculator uses automatically validated engineering formulas. Results are approximate and should be validated against site-specific conditions, applicable codes, and professional engineering judgment
Related Tools
BIM Structural Beam Flexural Strength Capacity (AISC LRFD) calculator
BIM Structural Beam Shear Capacity (LRFD) for Steel I-Beams calculator
BIM Structural Beam Flexural Moment Capacity (LRFD) calculator
BIM Element Spatial Proximity Collision Risk Predictor Calculator
BIM MEP Duct Sizing Efficiency Optimizer — Pressure Drop Calculation Calculator
BIM MEP Pipe Network Hydraulic Balance Diagnostic Index calculator
Browse More Tools
Explore the full index of engineering calculators on this vertical site.